The Lorient high performance letterplate assembly has been tested in accordance with BS 476 Pt. 22 and has been shown to provide in excess of 60 minutes protection against fire.

  • It is internally sealed so that the unit will not compromise the smoke integrity of the door when tested in accordance with BS 476 Pt. 31.1
     
  • It can be supplied with a range of optional security devices (please refer to brochure for further details). Several models of this letterplate are available to suit different thicknesses of door.

Max/min door thickness (t):

  • 42mm - 47mm: LRJ 8042F or LRJ 8042S
  • 47mm - 52mm: LRJ 8047F or LRJ 8047S
  • 52mm - 57mm: LRJ 8052F or LRJ 8052S

Note: Suffix F indicates fire protection
Suffix S indicates fire and smoke protection.

  • external height (h): 80mm
  • external width (w): 312mm
  • door aperture size: 270mm x 60mm
  • letter flaps: for 30 mins, aluminium only
  • for 60 mins, brushed stainless or brass